Monitor Config Reference¶
Understanding how to configure a Ceph Monitor is an important part of building a reliable Ceph Storage Cluster. All Ceph Storage Clusters have at least one monitor. A monitor configuration usually remains fairly consistent, but you can add, remove or replace a monitor in a cluster. See Adding/Removing a Monitor and Add/Remove a Monitor (ceph-deploy) for details.
Background¶
Ceph Monitors maintain a “master copy” of the cluster map, which means a Ceph Client can determine the location of all Ceph Monitors, Ceph OSD Daemons, and Ceph Metadata Servers just by connecting to one Ceph Monitor and retrieving a current cluster map. Before Ceph Clients can read from or write to Ceph OSD Daemons or Ceph Metadata Servers, they must connect to a Ceph Monitor first. With a current copy of the cluster map and the CRUSH algorithm, a Ceph Client can compute the location for any object. The ability to compute object locations allows a Ceph Client to talk directly to Ceph OSD Daemons, which is a very important aspect of Ceph’s high scalability and performance. See Scalability and High Availability for additional details.
The primary role of the Ceph Monitor is to maintain a master copy of the cluster map. Ceph Monitors also provide authentication and logging services. Ceph Monitors write all changes in the monitor services to a single Paxos instance, and Paxos writes the changes to a key/value store for strong consistency. Ceph Monitors can query the most recent version of the cluster map during sync operations. Ceph Monitors leverage the key/value store’s snapshots and iterators (using leveldb) to perform store-wide synchronization.
Deprecated since version version: 0.58
In Ceph versions 0.58 and earlier, Ceph Monitors use a Paxos instance for each service and store the map as a file.
Cluster Maps¶
The cluster map is a composite of maps, including the monitor map, the OSD map,
the placement group map and the metadata server map. The cluster map tracks a
number of important things: which processes are in
the Ceph Storage Cluster;
which processes that are in
the Ceph Storage Cluster are up
and running
or down
; whether, the placement groups are active
or inactive
, and
clean
or in some other state; and, other details that reflect the current
state of the cluster such as the total amount of storage space, and the amount
of storage used.
When there is a significant change in the state of the cluster–e.g., a Ceph OSD Daemon goes down, a placement group falls into a degraded state, etc.–the cluster map gets updated to reflect the current state of the cluster. Additionally, the Ceph Monitor also maintains a history of the prior states of the cluster. The monitor map, OSD map, placement group map and metadata server map each maintain a history of their map versions. We call each version an “epoch.”
When operating your Ceph Storage Cluster, keeping track of these states is an important part of your system administration duties. See Monitoring a Cluster and Monitoring OSDs and PGs for additional details.
Monitor Quorum¶
Our Configuring ceph section provides a trivial Ceph configuration file that provides for one monitor in the test cluster. A cluster will run fine with a single monitor; however, a single monitor is a single-point-of-failure. To ensure high availability in a production Ceph Storage Cluster, you should run Ceph with multiple monitors so that the failure of a single monitor WILL NOT bring down your entire cluster.
When a Ceph Storage Cluster runs multiple Ceph Monitors for high availability, Ceph Monitors use Paxos to establish consensus about the master cluster map. A consensus requires a majority of monitors running to establish a quorum for consensus about the cluster map (e.g., 1; 2 out of 3; 3 out of 5; 4 out of 6; etc.).
mon force quorum join
- Description
Force monitor to join quorum even if it has been previously removed from the map
- Type
Boolean
- Default
False
Consistency¶
When you add monitor settings to your Ceph configuration file, you need to be aware of some of the architectural aspects of Ceph Monitors. Ceph imposes strict consistency requirements for a Ceph monitor when discovering another Ceph Monitor within the cluster. Whereas, Ceph Clients and other Ceph daemons use the Ceph configuration file to discover monitors, monitors discover each other using the monitor map (monmap), not the Ceph configuration file.
A Ceph Monitor always refers to the local copy of the monmap when discovering
other Ceph Monitors in the Ceph Storage Cluster. Using the monmap instead of the
Ceph configuration file avoids errors that could break the cluster (e.g., typos
in ceph.conf
when specifying a monitor address or port). Since monitors use
monmaps for discovery and they share monmaps with clients and other Ceph
daemons, the monmap provides monitors with a strict guarantee that their
consensus is valid.
Strict consistency also applies to updates to the monmap. As with any other updates on the Ceph Monitor, changes to the monmap always run through a distributed consensus algorithm called Paxos. The Ceph Monitors must agree on each update to the monmap, such as adding or removing a Ceph Monitor, to ensure that each monitor in the quorum has the same version of the monmap. Updates to the monmap are incremental so that Ceph Monitors have the latest agreed upon version, and a set of previous versions. Maintaining a history enables a Ceph Monitor that has an older version of the monmap to catch up with the current state of the Ceph Storage Cluster.
If Ceph Monitors discovered each other through the Ceph configuration file instead of through the monmap, it would introduce additional risks because the Ceph configuration files are not updated and distributed automatically. Ceph Monitors might inadvertently use an older Ceph configuration file, fail to recognize a Ceph Monitor, fall out of a quorum, or develop a situation where Paxos is not able to determine the current state of the system accurately.
Bootstrapping Monitors¶
In most configuration and deployment cases, tools that deploy Ceph may help
bootstrap the Ceph Monitors by generating a monitor map for you (e.g.,
ceph-deploy
, etc). A Ceph Monitor requires a few explicit
settings:
Filesystem ID: The
fsid
is the unique identifier for your object store. Since you can run multiple clusters on the same hardware, you must specify the unique ID of the object store when bootstrapping a monitor. Deployment tools usually do this for you (e.g.,ceph-deploy
can call a tool likeuuidgen
), but you may specify thefsid
manually too.Monitor ID: A monitor ID is a unique ID assigned to each monitor within the cluster. It is an alphanumeric value, and by convention the identifier usually follows an alphabetical increment (e.g.,
a
,b
, etc.). This can be set in a Ceph configuration file (e.g.,[mon.a]
,[mon.b]
, etc.), by a deployment tool, or using theceph
commandline.Keys: The monitor must have secret keys. A deployment tool such as
ceph-deploy
usually does this for you, but you may perform this step manually too. See Monitor Keyrings for details.
For additional details on bootstrapping, see Bootstrapping a Monitor.
Configuring Monitors¶
To apply configuration settings to the entire cluster, enter the configuration
settings under [global]
. To apply configuration settings to all monitors in
your cluster, enter the configuration settings under [mon]
. To apply
configuration settings to specific monitors, specify the monitor instance
(e.g., [mon.a]
). By convention, monitor instance names use alpha notation.
[global]
[mon]
[mon.a]
[mon.b]
[mon.c]
Minimum Configuration¶
The bare minimum monitor settings for a Ceph monitor via the Ceph configuration
file include a hostname and a monitor address for each monitor. You can configure
these under [mon]
or under the entry for a specific monitor.
[global]
mon host = 10.0.0.2,10.0.0.3,10.0.0.4
[mon.a]
host = hostname1
mon addr = 10.0.0.10:6789
See the Network Configuration Reference for details.
Note
This minimum configuration for monitors assumes that a deployment
tool generates the fsid
and the mon.
key for you.
Once you deploy a Ceph cluster, you SHOULD NOT change the IP address of the monitors. However, if you decide to change the monitor’s IP address, you must follow a specific procedure. See Changing a Monitor’s IP Address for details.
Monitors can also be found by clients using DNS SRV records. See Monitor lookup through DNS for details.
Cluster ID¶
Each Ceph Storage Cluster has a unique identifier (fsid
). If specified, it
usually appears under the [global]
section of the configuration file.
Deployment tools usually generate the fsid
and store it in the monitor map,
so the value may not appear in a configuration file. The fsid
makes it
possible to run daemons for multiple clusters on the same hardware.
fsid
- Description
The cluster ID. One per cluster.
- Type
UUID
- Required
Yes.
- Default
N/A. May be generated by a deployment tool if not specified.
Note
Do not set this value if you use a deployment tool that does it for you.
Initial Members¶
We recommend running a production Ceph Storage Cluster with at least three Ceph Monitors to ensure high availability. When you run multiple monitors, you may specify the initial monitors that must be members of the cluster in order to establish a quorum. This may reduce the time it takes for your cluster to come online.
[mon]
mon initial members = a,b,c
mon initial members
- Description
The IDs of initial monitors in a cluster during startup. If specified, Ceph requires an odd number of monitors to form an initial quorum (e.g., 3).
- Type
String
- Default
None
Note
A majority of monitors in your cluster must be able to reach each other in order to establish a quorum. You can decrease the initial number of monitors to establish a quorum with this setting.
Data¶
Ceph provides a default path where Ceph Monitors store data. For optimal
performance in a production Ceph Storage Cluster, we recommend running Ceph
Monitors on separate hosts and drives from Ceph OSD Daemons. As leveldb is using
mmap()
for writing the data, Ceph Monitors flush their data from memory to disk
very often, which can interfere with Ceph OSD Daemon workloads if the data
store is co-located with the OSD Daemons.
In Ceph versions 0.58 and earlier, Ceph Monitors store their data in files. This
approach allows users to inspect monitor data with common tools like ls
and cat
. However, it doesn’t provide strong consistency.
In Ceph versions 0.59 and later, Ceph Monitors store their data as key/value pairs. Ceph Monitors require ACID transactions. Using a data store prevents recovering Ceph Monitors from running corrupted versions through Paxos, and it enables multiple modification operations in one single atomic batch, among other advantages.
Generally, we do not recommend changing the default data location. If you modify
the default location, we recommend that you make it uniform across Ceph Monitors
by setting it in the [mon]
section of the configuration file.
mon data
- Description
The monitor’s data location.
- Type
String
- Default
/var/lib/ceph/mon/$cluster-$id
mon data size warn
- Description
Issue a
HEALTH_WARN
in cluster log when the monitor’s data store goes over 15GB.- Type
Integer
- Default
15*1024*1024*1024
mon data avail warn
- Description
Issue a
HEALTH_WARN
in cluster log when the available disk space of monitor’s data store is lower or equal to this percentage.- Type
Integer
- Default
30
mon data avail crit
- Description
Issue a
HEALTH_ERR
in cluster log when the available disk space of monitor’s data store is lower or equal to this percentage.- Type
Integer
- Default
5
mon warn on cache pools without hit sets
- Description
Issue a
HEALTH_WARN
in cluster log if a cache pool does not have thehit_set_type
value configured. See hit_set_type for more details.- Type
Boolean
- Default
True
mon warn on crush straw calc version zero
- Description
Issue a
HEALTH_WARN
in cluster log if the CRUSH’sstraw_calc_version
is zero. See CRUSH map tunables for details.- Type
Boolean
- Default
True
mon warn on legacy crush tunables
- Description
Issue a
HEALTH_WARN
in cluster log if CRUSH tunables are too old (older thanmon_min_crush_required_version
)- Type
Boolean
- Default
True
mon crush min required version
- Description
The minimum tunable profile version required by the cluster. See CRUSH map tunables for details.
- Type
String
- Default
hammer
mon warn on osd down out interval zero
- Description
Issue a
HEALTH_WARN
in cluster log ifmon osd down out interval
is zero. Having this option set to zero on the leader acts much like thenoout
flag. It’s hard to figure out what’s going wrong with clusters without thenoout
flag set but acting like that just the same, so we report a warning in this case.- Type
Boolean
- Default
True
mon warn on slow ping ratio
- Description
Issue a
HEALTH_WARN
in cluster log if any heartbeat between OSDs exceedsmon warn on slow ping ratio
ofosd heartbeat grace
. The default is 5%.- Type
Float
- Default
0.05
mon warn on slow ping time
- Description
Override
mon warn on slow ping ratio
with a specific value. Issue aHEALTH_WARN
in cluster log if any heartbeat between OSDs exceedsmon warn on slow ping time
milliseconds. The default is 0 (disabled).- Type
Integer
- Default
0
mon warn on pool no redundancy
- Description
Issue a
HEALTH_WARN
in cluster log if any pool is configured with no replicas.- Type
Boolean
- Default
True
mon cache target full warn ratio
- Description
Position between pool’s
cache_target_full
andtarget_max_object
where we start warning- Type
Float
- Default
0.66
mon health to clog
- Description
Enable sending health summary to cluster log periodically.
- Type
Boolean
- Default
True
mon health to clog tick interval
- Description
How often (in seconds) the monitor send health summary to cluster log (a non-positive number disables it). If current health summary is empty or identical to the last time, monitor will not send it to cluster log.
- Type
Float
- Default
60.0
mon health to clog interval
- Description
How often (in seconds) the monitor send health summary to cluster log (a non-positive number disables it). Monitor will always send the summary to cluster log no matter if the summary changes or not.
- Type
Integer
- Default
3600
Storage Capacity¶
When a Ceph Storage Cluster gets close to its maximum capacity (i.e., mon osd
full ratio
), Ceph prevents you from writing to or reading from Ceph OSD
Daemons as a safety measure to prevent data loss. Therefore, letting a
production Ceph Storage Cluster approach its full ratio is not a good practice,
because it sacrifices high availability. The default full ratio is .95
, or
95% of capacity. This a very aggressive setting for a test cluster with a small
number of OSDs.
Tip
When monitoring your cluster, be alert to warnings related to the
nearfull
ratio. This means that a failure of some OSDs could result
in a temporary service disruption if one or more OSDs fails. Consider adding
more OSDs to increase storage capacity.
A common scenario for test clusters involves a system administrator removing a
Ceph OSD Daemon from the Ceph Storage Cluster to watch the cluster rebalance;
then, removing another Ceph OSD Daemon, and so on until the Ceph Storage Cluster
eventually reaches the full ratio and locks up. We recommend a bit of capacity
planning even with a test cluster. Planning enables you to gauge how much spare
capacity you will need in order to maintain high availability. Ideally, you want
to plan for a series of Ceph OSD Daemon failures where the cluster can recover
to an active + clean
state without replacing those Ceph OSD Daemons
immediately. You can run a cluster in an active + degraded
state, but this
is not ideal for normal operating conditions.
The following diagram depicts a simplistic Ceph Storage Cluster containing 33
Ceph Nodes with one Ceph OSD Daemon per host, each Ceph OSD Daemon reading from
and writing to a 3TB drive. So this exemplary Ceph Storage Cluster has a maximum
actual capacity of 99TB. With a mon osd full ratio
of 0.95
, if the Ceph
Storage Cluster falls to 5TB of remaining capacity, the cluster will not allow
Ceph Clients to read and write data. So the Ceph Storage Cluster’s operating
capacity is 95TB, not 99TB.
It is normal in such a cluster for one or two OSDs to fail. A less frequent but
reasonable scenario involves a rack’s router or power supply failing, which
brings down multiple OSDs simultaneously (e.g., OSDs 7-12). In such a scenario,
you should still strive for a cluster that can remain operational and achieve an
active + clean
state–even if that means adding a few hosts with additional
OSDs in short order. If your capacity utilization is too high, you may not lose
data, but you could still sacrifice data availability while resolving an outage
within a failure domain if capacity utilization of the cluster exceeds the full
ratio. For this reason, we recommend at least some rough capacity planning.
Identify two numbers for your cluster:
The number of OSDs.
The total capacity of the cluster
If you divide the total capacity of your cluster by the number of OSDs in your cluster, you will find the mean average capacity of an OSD within your cluster. Consider multiplying that number by the number of OSDs you expect will fail simultaneously during normal operations (a relatively small number). Finally multiply the capacity of the cluster by the full ratio to arrive at a maximum operating capacity; then, subtract the number of amount of data from the OSDs you expect to fail to arrive at a reasonable full ratio. Repeat the foregoing process with a higher number of OSD failures (e.g., a rack of OSDs) to arrive at a reasonable number for a near full ratio.
The following settings only apply on cluster creation and are then stored in the OSDMap.
[global]
mon osd full ratio = .80
mon osd backfillfull ratio = .75
mon osd nearfull ratio = .70
mon osd full ratio
- Description
The percentage of disk space used before an OSD is considered
full
.- Type
Float
- Default
0.95
mon osd backfillfull ratio
- Description
The percentage of disk space used before an OSD is considered too
full
to backfill.- Type
Float
- Default
0.90
mon osd nearfull ratio
- Description
The percentage of disk space used before an OSD is considered
nearfull
.- Type
Float
- Default
0.85
Tip
If some OSDs are nearfull, but others have plenty of capacity, you may have a problem with the CRUSH weight for the nearfull OSDs.
Tip
These settings only apply during cluster creation. Afterwards they need
to be changed in the OSDMap using ceph osd set-nearfull-ratio
and
ceph osd set-full-ratio
Heartbeat¶
Ceph monitors know about the cluster by requiring reports from each OSD, and by receiving reports from OSDs about the status of their neighboring OSDs. Ceph provides reasonable default settings for monitor/OSD interaction; however, you may modify them as needed. See Monitor/OSD Interaction for details.
Monitor Store Synchronization¶
When you run a production cluster with multiple monitors (recommended), each monitor checks to see if a neighboring monitor has a more recent version of the cluster map (e.g., a map in a neighboring monitor with one or more epoch numbers higher than the most current epoch in the map of the instant monitor). Periodically, one monitor in the cluster may fall behind the other monitors to the point where it must leave the quorum, synchronize to retrieve the most current information about the cluster, and then rejoin the quorum. For the purposes of synchronization, monitors may assume one of three roles:
Leader: The Leader is the first monitor to achieve the most recent Paxos version of the cluster map.
Provider: The Provider is a monitor that has the most recent version of the cluster map, but wasn’t the first to achieve the most recent version.
Requester: A Requester is a monitor that has fallen behind the leader and must synchronize in order to retrieve the most recent information about the cluster before it can rejoin the quorum.
These roles enable a leader to delegate synchronization duties to a provider, which prevents synchronization requests from overloading the leader–improving performance. In the following diagram, the requester has learned that it has fallen behind the other monitors. The requester asks the leader to synchronize, and the leader tells the requester to synchronize with a provider.
Synchronization always occurs when a new monitor joins the cluster. During runtime operations, monitors may receive updates to the cluster map at different times. This means the leader and provider roles may migrate from one monitor to another. If this happens while synchronizing (e.g., a provider falls behind the leader), the provider can terminate synchronization with a requester.
Once synchronization is complete, Ceph requires trimming across the cluster.
Trimming requires that the placement groups are active + clean
.
mon sync timeout
- Description
Number of seconds the monitor will wait for the next update message from its sync provider before it gives up and bootstrap again.
- Type
Double
- Default
60.0
mon sync max payload size
- Description
The maximum size for a sync payload (in bytes).
- Type
32-bit Integer
- Default
1048576
paxos max join drift
- Description
The maximum Paxos iterations before we must first sync the monitor data stores. When a monitor finds that its peer is too far ahead of it, it will first sync with data stores before moving on.
- Type
Integer
- Default
10
paxos stash full interval
- Description
How often (in commits) to stash a full copy of the PaxosService state. Current this setting only affects
mds
,mon
,auth
andmgr
PaxosServices.- Type
Integer
- Default
25
paxos propose interval
- Description
Gather updates for this time interval before proposing a map update.
- Type
Double
- Default
1.0
paxos min
- Description
The minimum number of paxos states to keep around
- Type
Integer
- Default
500
paxos min wait
- Description
The minimum amount of time to gather updates after a period of inactivity.
- Type
Double
- Default
0.05
paxos trim min
- Description
Number of extra proposals tolerated before trimming
- Type
Integer
- Default
250
paxos trim max
- Description
The maximum number of extra proposals to trim at a time
- Type
Integer
- Default
500
paxos service trim min
- Description
The minimum amount of versions to trigger a trim (0 disables it)
- Type
Integer
- Default
250
paxos service trim max
- Description
The maximum amount of versions to trim during a single proposal (0 disables it)
- Type
Integer
- Default
500
mon mds force trim to
- Description
Force monitor to trim mdsmaps to this point (0 disables it. dangerous, use with care)
- Type
Integer
- Default
0
mon osd force trim to
- Description
Force monitor to trim osdmaps to this point, even if there is PGs not clean at the specified epoch (0 disables it. dangerous, use with care)
- Type
Integer
- Default
0
mon osd cache size
- Description
The size of osdmaps cache, not to rely on underlying store’s cache
- Type
Integer
- Default
500
mon election timeout
- Description
On election proposer, maximum waiting time for all ACKs in seconds.
- Type
Float
- Default
5.00
mon lease
- Description
The length (in seconds) of the lease on the monitor’s versions.
- Type
Float
- Default
5.00
mon lease renew interval factor
- Description
mon lease
*mon lease renew interval factor
will be the interval for the Leader to renew the other monitor’s leases. The factor should be less than1.0
.- Type
Float
- Default
0.60
mon lease ack timeout factor
- Description
The Leader will wait
mon lease
*mon lease ack timeout factor
for the Providers to acknowledge the lease extension.- Type
Float
- Default
2.00
mon accept timeout factor
- Description
The Leader will wait
mon lease
*mon accept timeout factor
for the Requester(s) to accept a Paxos update. It is also used during the Paxos recovery phase for similar purposes.- Type
Float
- Default
2.00
mon min osdmap epochs
- Description
Minimum number of OSD map epochs to keep at all times.
- Type
32-bit Integer
- Default
500
mon max log epochs
- Description
Maximum number of Log epochs the monitor should keep.
- Type
32-bit Integer
- Default
500
Clock¶
Ceph daemons pass critical messages to each other, which must be processed before daemons reach a timeout threshold. If the clocks in Ceph monitors are not synchronized, it can lead to a number of anomalies. For example:
Daemons ignoring received messages (e.g., timestamps outdated)
Timeouts triggered too soon/late when a message wasn’t received in time.
See Monitor Store Synchronization for details.
Tip
You SHOULD install NTP on your Ceph monitor hosts to ensure that the monitor cluster operates with synchronized clocks.
Clock drift may still be noticeable with NTP even though the discrepancy is not yet harmful. Ceph’s clock drift / clock skew warnings may get triggered even though NTP maintains a reasonable level of synchronization. Increasing your clock drift may be tolerable under such circumstances; however, a number of factors such as workload, network latency, configuring overrides to default timeouts and the Monitor Store Synchronization settings may influence the level of acceptable clock drift without compromising Paxos guarantees.
Ceph provides the following tunable options to allow you to find acceptable values.
mon tick interval
- Description
A monitor’s tick interval in seconds.
- Type
32-bit Integer
- Default
5
mon clock drift allowed
- Description
The clock drift in seconds allowed between monitors.
- Type
Float
- Default
0.05
mon clock drift warn backoff
- Description
Exponential backoff for clock drift warnings
- Type
Float
- Default
5.00
mon timecheck interval
- Description
The time check interval (clock drift check) in seconds for the Leader.
- Type
Float
- Default
300.00
mon timecheck skew interval
- Description
The time check interval (clock drift check) in seconds when in presence of a skew in seconds for the Leader.
- Type
Float
- Default
30.00
Client¶
mon client hunt interval
- Description
The client will try a new monitor every
N
seconds until it establishes a connection.- Type
Double
- Default
3.00
mon client ping interval
- Description
The client will ping the monitor every
N
seconds.- Type
Double
- Default
10.00
mon client max log entries per message
- Description
The maximum number of log entries a monitor will generate per client message.
- Type
Integer
- Default
1000
mon client bytes
- Description
The amount of client message data allowed in memory (in bytes).
- Type
64-bit Integer Unsigned
- Default
100ul << 20
Pool settings¶
Since version v0.94 there is support for pool flags which allow or disallow changes to be made to pools.
Monitors can also disallow removal of pools if configured that way.
mon allow pool delete
- Description
If the monitors should allow pools to be removed. Regardless of what the pool flags say.
- Type
Boolean
- Default
false
osd pool default ec fast read
- Description
Whether to turn on fast read on the pool or not. It will be used as the default setting of newly created erasure coded pools if
fast_read
is not specified at create time.- Type
Boolean
- Default
false
osd pool default flag hashpspool
- Description
Set the hashpspool flag on new pools
- Type
Boolean
- Default
true
osd pool default flag nodelete
- Description
Set the nodelete flag on new pools. Prevents allow pool removal with this flag in any way.
- Type
Boolean
- Default
false
osd pool default flag nopgchange
- Description
Set the nopgchange flag on new pools. Does not allow the number of PGs to be changed for a pool.
- Type
Boolean
- Default
false
osd pool default flag nosizechange
- Description
Set the nosizechange flag on new pools. Does not allow the size to be changed of pool.
- Type
Boolean
- Default
false
For more information about the pool flags see Pool values.
Miscellaneous¶
mon max osd
- Description
The maximum number of OSDs allowed in the cluster.
- Type
32-bit Integer
- Default
10000
mon globalid prealloc
- Description
The number of global IDs to pre-allocate for clients and daemons in the cluster.
- Type
32-bit Integer
- Default
10000
mon subscribe interval
- Description
The refresh interval (in seconds) for subscriptions. The subscription mechanism enables obtaining the cluster maps and log information.
- Type
Double
- Default
86400.00
mon stat smooth intervals
- Description
Ceph will smooth statistics over the last
N
PG maps.- Type
Integer
- Default
6
mon probe timeout
- Description
Number of seconds the monitor will wait to find peers before bootstrapping.
- Type
Double
- Default
2.00
mon daemon bytes
- Description
The message memory cap for metadata server and OSD messages (in bytes).
- Type
64-bit Integer Unsigned
- Default
400ul << 20
mon max log entries per event
- Description
The maximum number of log entries per event.
- Type
Integer
- Default
4096
mon osd prime pg temp
- Description
Enables or disable priming the PGMap with the previous OSDs when an out OSD comes back into the cluster. With the
true
setting the clients will continue to use the previous OSDs until the newly in OSDs as that PG peered.- Type
Boolean
- Default
true
mon osd prime pg temp max time
- Description
How much time in seconds the monitor should spend trying to prime the PGMap when an out OSD comes back into the cluster.
- Type
Float
- Default
0.50
mon osd prime pg temp max time estimate
- Description
Maximum estimate of time spent on each PG before we prime all PGs in parallel.
- Type
Float
- Default
0.25
mon mds skip sanity
- Description
Skip safety assertions on FSMap (in case of bugs where we want to continue anyway). Monitor terminates if the FSMap sanity check fails, but we can disable it by enabling this option.
- Type
Boolean
- Default
False
mon max mdsmap epochs
- Description
The maximum amount of mdsmap epochs to trim during a single proposal.
- Type
Integer
- Default
500
mon config key max entry size
- Description
The maximum size of config-key entry (in bytes)
- Type
Integer
- Default
65536
mon scrub interval
- Description
How often (in seconds) the monitor scrub its store by comparing the stored checksums with the computed ones of all the stored keys.
- Type
Integer
- Default
3600*24
mon scrub max keys
- Description
The maximum number of keys to scrub each time.
- Type
Integer
- Default
100
mon compact on start
- Description
Compact the database used as Ceph Monitor store on
ceph-mon
start. A manual compaction helps to shrink the monitor database and improve the performance of it if the regular compaction fails to work.- Type
Boolean
- Default
False
mon compact on bootstrap
- Description
Compact the database used as Ceph Monitor store on on bootstrap. Monitor starts probing each other for creating a quorum after bootstrap. If it times out before joining the quorum, it will start over and bootstrap itself again.
- Type
Boolean
- Default
False
mon compact on trim
- Description
Compact a certain prefix (including paxos) when we trim its old states.
- Type
Boolean
- Default
True
mon cpu threads
- Description
Number of threads for performing CPU intensive work on monitor.
- Type
Integer
- Default
4
mon osd mapping pgs per chunk
- Description
We calculate the mapping from placement group to OSDs in chunks. This option specifies the number of placement groups per chunk.
- Type
Integer
- Default
4096
mon session timeout
- Description
Monitor will terminate inactive sessions stay idle over this time limit.
- Type
Integer
- Default
300
mon osd cache size min
- Description
The minimum amount of bytes to be kept mapped in memory for osd monitor caches.
- Type
64-bit Integer
- Default
134217728
mon memory target
- Description
The amount of bytes pertaining to osd monitor caches and kv cache to be kept mapped in memory with cache auto-tuning enabled.
- Type
64-bit Integer
- Default
2147483648
mon memory autotune
- Description
Autotune the cache memory being used for osd monitors and kv database.
- Type
Boolean
- Default
True