iSCSI Initiator for Microsoft Windows

Prerequisite:

  • Microsoft Windows Server 2016

iSCSI Initiator, Discovery and Setup:

  1. Install the iSCSI initiator driver and MPIO tools.

  2. Launch the MPIO program, click on the “Discover Multi-Paths” tab, check the “Add support for iSCSI devices” box, and click “Add”. This will require a reboot.

  3. On the iSCSI Initiator Properties window, on the “Discovery” tab, add a target portal. Enter the IP address or DNS name and Port of the Ceph iSCSI gateway.

  4. On the “Targets” tab, select the target and click on “Connect”.

  5. On the “Connect To Target” window, select the “Enable multi-path” option, and click the “Advanced” button.

  6. Under the “Connet using” section, select a “Target portal IP” . Select the “Enable CHAP login on” and enter the “Name” and “Target secret” values from the Ceph iSCSI Ansible client credentials section, and click OK.

  7. Repeat steps 5 and 6 for each target portal defined when setting up the iSCSI gateway.

Multipath IO Setup:

Configuring the MPIO load balancing policy, setting the timeout and retry options are using PowerShell with the mpclaim command. The rest is done in the iSCSI Initiator tool.

Note

It is recommended to increase the PDORemovePeriod option to 120 seconds from PowerShell. This value might need to be adjusted based on the application. When all paths are down, and 120 seconds expires, the operating system will start failing IO requests.

Set-MPIOSetting -NewPDORemovePeriod 120
mpclaim.exe -l -m 1
mpclaim -s -m
MSDSM-wide Load Balance Policy: Fail Over Only
  1. Using the iSCSI Initiator tool, from the “Targets” tab, click on the “Devices…” button.

  2. From the Devices window, select a disk and click the “MPIO…” button.

  3. On the “Device Details” window the paths to each target portal is displayed. If using the ceph-ansible setup method, the iSCSI gateway will use ALUA to tell the iSCSI initiator which path and iSCSI gateway should be used as the primary path. The Load Balancing Policy “Fail Over Only” must be selected

mpclaim -s -d $MPIO_DISK_ID

Note

For the ceph-ansible setup method, there will be one Active/Optimized path which is the path to the iSCSI gateway node that owns the LUN, and there will be an Active/Unoptimized path for each other iSCSI gateway node.

Tuning:

Consider using the following registry settings:

  • Windows Disk Timeout

    HKEY_LOCAL_MACHINE\System\CurrentControlSet\Services\Disk
    
    TimeOutValue = 65
    
  • Microsoft iSCSI Initiator Driver

    HKEY_LOCAL_MACHINE\\SYSTEM\CurrentControlSet\Control\Class\{4D36E97B-E325-11CE-BFC1-08002BE10318}\<Instance_Number>\Parameters
    
    LinkDownTime = 25
    SRBTimeoutDelta = 15